You are here : HOME > Products > Industrial > Safety > DK-12

Product Features  
  Overhead presence detection on swinging and industrial doors utilizing active infrared technology.  
     
 
  • Six selectable patterns accommodate all single doors or a pair of doors.

  • Adjustable self-adaptation mode learns background changes (30 sec. to 25 min.)

  • Anti-vandalism, sturdy aluminum housing.

11111

 

 
Product Technical Specifications  
 
Description Specification
Installation height: 6’ to 10’
Wide detection pattern: 6’ W x 4’ D (see pattern chart)

Narrow detection pattern

(center, left, right):

2.5’ W x 3.5’ D (see pattern chart)
Asymmetrical detection pattern (left, right): 4’ W x 4’ D (see pattern chart)
Mounting angle: 20° - 26° - 32°
Power supply: 12 - 24 V AC or DC +/- 10 %
Frequency: 50 or 60 Hz
Consumption: 2 W
Max. voltage - relay contacts: 60 V DC - 125 V AC
Max. current - relay contacts: 8 AMP - resistive
Max. Power supply: 30 Watts (DC), 125 VA(AC)
Hold time: 1 to 10 seconds
Operating temperature: -30°F to 131°F
Immunity: Immune to electrical and radio frequency interference
Cable: 3 feet of 6 conductor cable
Weight: 1 lb., 11 oz.
Dimensions: 11 ¼" L x 2¼" D x 3" H
Material: Aluminum & ABS plastic
Housing color: Black
 
 
11111
 
Product Sensing Field  
 
1
2
   
 
Industrial Doors
Swinging Doors
   
     
 
11111
 
Related Products  
 
RelPrd
RelPrd
RelPrd
RelPrd
   
     
 
RelPrd
RelPrd
RelPrd
RelPrd
   
 
Remote
Transformer
   
 
11111
 
Product Architectural Specifications  
 

DK-12 presence sensor:  Active infrared presence sensor that utilizes diffused infrared technology.

a. The DK-12 sensor shall detect stationary humans or equivalent

    within the sensing pattern.

b. The sensor shall have a sensing pattern that is fully adjustable

    by remote control, for sensitivity and pattern width. Pattern size

    adjustments made by masking a lens shall not be acceptable.

c. When used with BEA’s lockout relay, the DK-12 shall provide 2

    independently adjustable patterns: One for the door closed

    position, and one for the door open position. The sensor shall

    be capable of different depth angles relative to the face of the

    door.

d. Sensor Dimensions: 11 ¼ ”W x 2 ¼ ”H x 3”D

e. Mounting Height: 7’ to 10’ above finished floor.

f. Finish: Black anodized aluminum extrusion / black ABS end-

    caps / infrared lens

g. Operation: The DK-12, when in detection, shall prevent

    activation while the door is in the closed position, and shall

    provide a hold open function for a door in the open position.

 
 
11111
 
Downloads
1
1
1
1
1
1
1
1
1
 
 
 
© 1987-2010 BEA | All rights reserved